Eco Surface Solutions

External Cork Wall Coatings

1930s semi nearly doubles heat-retention time after spray cork retrofit

A 1930s solid-brick semi monitored with HomeLINK IoT sensors for 12 months pre- and post-retrofit. SprayCork nearly doubled the property's heat-retention time, dropping heat-loss risk from high to medium/low across every monitored room.

1930s semi nearly doubles heat-retention time after spray cork retrofit — York, North Yorkshire
Location
York, North Yorkshire
Property
1930s solid-brick semi-detached
Area
Full external elevations
Duration
5 days
Completed
Aug 2024

The challenge

EPC rated D (60), with solid brick walls, no insulation and failing render to the rear extension. Conventional 100–150 mm EWI would have covered exposed brickwork detail and forced removal/reinstatement of every window. The owners needed a thin, breathable, evidence-backed solution.

Our solution

Existing failed render hacked off, brickwork repaired and primed, then 6–8 mm of CorkSol SprayCork applied over the prepared substrate by approved applicator JMB Plastering Specialists. Existing monocouche elsewhere was simply over-sprayed — no demolition needed. Performance validated using HomeLINK environmental sensors recording at 15-minute intervals.

Learn about External Cork Wall Coatings

Results

  • Time to lose 1°C nearly doubled — from 28 minutes pre-retrofit to 53 minutes post-retrofit
  • Heat-loss risk dropped from high in all three monitored rooms to medium in two and low in one
  • Heat dissipation improved across every room — over 50% improvement in the worst-performing room
  • Achieved without covering lower brickwork or removing windows